Filter Results By:

Products

Applications

Manufacturers

Showing results: 136 - 150 of 162 items found.

  • Charged Fluids or Neutrals Simulation Software

    USim - Tech-X Corporation

    modeling framework that simulates the dynamics of charged fluids or neutrals. Using structured or unstructured meshes, USim quickly and accurately solves such basic problems as shock and instability capturing in inviscid, compressible neutral gas flows (Euler equations) or profile evolution in ionized plasmas (ideal MHD equations). supports: hydrodynamics, magnetohydrodynamics, Hall magnetohydrodynamics, two-fluid plasmas and Navier-Stokes and Maxwell's equations.

  • Vapor Concentration Monitor

    IR-300 Series - HORIBA, Ltd.

    Metal-Organic Chemical Vapor Deposition (MOCVD) is widely used in the manufacture of LEDs, optical devices and other components. Liquid and solid precursors are delivered to the reaction chamber by controlling the temperature, pressure and the carrier gas flow rate (bubbling method). Process results can be affected by changes especially in temperature and liquid level. The in-line IR-300 Series measures and reports the precursor concentration in real time.

  • Carbon Dioxide Quality Control System

    CDQC - Teledyne Analytical Instruments

    Teledyne’s Carbon Dioxide Quality Control (CDQC) system offers an integrated package to continuously monitor impurities in carbon dioxide (CO2). The plug-and-play design allows for the user to select only the gases and features of interest to maximize cost benefit and space.Front door viewing windows allow for view of all analyzer displays, flow and pressure settings. Stainless steel tube fitting connections and NPT or metric electrical ports as required are conveniently located in a central location for ease of access. Sample conditioning, utility gas provisions and integral calibration gas solenoid valves are standard.

  • Portable Gas Calibrator

    Model T750 - Teledyne Advanced Pollution Instrumentation

    The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.

  • Trace-Level Dilution Calibrator

    Model T700U - Teledyne Advanced Pollution Instrumentation

    The Model T700U is a microprocessor based calibrator for precision, trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero checks using up to 4 gas sources.In addition to the features of the Model T700, the Model T700U is designed for the demanding requirements of trace-level measurements. The ability to calibrate and verify linearity for NO2 at levels below 50 ppb is difficult with standard calibrators. To overcome this limitation, the Model T700U ozone generator operates in two modes; a high range with similar performance to the Model T700 ozone generator, and a low range, or "fractional" mode, for producing accurate ozone levels down to 3 ppb. To ensure the highest accuracy of NO2 output, the calibrator measures the ozone concentration prior to performing a GPT, and the range is selected automatically by the Model T700U based on ozone concentration and flow specified by the user.

  • Integrated Gas Alarm & Control System

    MCX-32 - Teledyne Gas & Flame Detection

    The MCX-32 controller features a flexible design that allows the user to customize a system by choosing from a selection of individually addressable field devices or use addressable input and output modules. Detcon’s full range of gas sensors (purchased separately) can be used to create a gas detection system consisting of toxic gas, combustible gas, and/or oxygen deficiency. A wide range of field devices such as liquid level, temperature, pressure, flow, etc., can also be configured for input to the control system. Four standard I/O modules are available: a 4-channel 4-20mA input module (DA-4), a 4-alarm relay output module (RL-4), a 4-channel 4-20mA output module (AO-4), and a 4-relay contact input module (DI-4). I/O modules are din-rail mounted and stackable allowing for seamless system expansion. The I/O modules may be mounted within the main system enclosure or in separate enclosures suitable for the area classification where installation will occur. In many cases using distributed I/O nodes can significantly reduce wiring and installation costs.

  • Corrosion Inhibitor Evaluation

    ASTM G202 - Metal Samples Company

    Metals Samples provides solutions to study the performance of corrosion inhibitors in the laboratory. The Rotating Cage is helpful in selecting corrosion inhibitors for use in oil and gas production pipelines and facilities, transmission pipelines, as well as in oil refineries. It simulates aggressive field flow conditions that cause localized pitting corrosion in a simple laboratory setup. The precision, i.e., repeatability and reproducibility, of the rotating cage has been established (ASTM G202).

  • Gas Analysis

    HPR-40 DSA - Hiden Analytical Ltd.

    Hiden Analytical offers class-leading gas monitoring solutions designed to obtain and quantify complex species in liquid samples. Our ultra-precision HPR-40 DSA is a compact membrane inlet mass spectrometer (MIMS) and a versatile instrument suited to dissolved and evolved species analysis. Direct probes, flow through probes and large circular membrane cells are available to address a broad application range in sediment, sea water, sludge and groundwater studies.

  • High Density Plasma Etching System for 200mm substrates

    Model DRIE-1200-LL-ICP - TEK-VAC INDUSTRIES Inc.

    Single process chamber for high rate plasma etching of 200mm wafers. Loadlocked. Stainless steel construction. Capabilities of smaller, multiple wafer throughput. Substrate materials include (but are not limited to) silicon, silicon oxynitrides, SiC, SiGe, Aluminum, and III-V compounds including GaAs, GaN, GaP, and InP. Stable plasma generation capabilities to below 1 mTorr. Five, Six, or Eight gas mass flow controllers are standard. Expanded or reduced numbers are available upon request.

  • Control Devices

    Circutor, sa

    Solutions for monitoring and recording any value you wish to manage (electricity, water, gas consumption, temperatures, flow rates, pressures, units produced, etc.), either through communications or through pulse logger systems. The control system family contains the LINE solution to create a comprehensive energy management systems (SGEi), LM pulse loggers and MDC controllers to avoid surcharges in the electric bill by preventing the contracted capacity in electrical installations from being exceeded.

  • MASTER FUEL PRESSURE TEST KIT

    FIT550 - Matco Tools

    *Performs running, residual, rail and flow rate pressure tests*Large, easy-to-read 3-1/2" dual-scale gauge reads 0-100psi and 0-700 kPa*Kit includes: 50+ adapters, fittings, 48" hose, pressure relief and fuel discharge hose to test most domestic and foreign fuel injection systems*Also includes quick release couplers and adapters to fit other fuel injection test kits*For use with gas engines only

  • Oxygen Monitoring System

    Oxytron 2000 - Bacharach, Inc.

    The Neutronics Oxytron 2000 is a custom-configured instrument designed to automatically control oxygen in process applications. When combined with a properly designed sample conditioning package, the Oxytron 2000 provides reliable measurement and control of oxygen, keeping it at a safe level by controlling the flow of inert gas into the process. Originally developed for one of the country’s largest chemical manufacturers, the Oxytron 2000 has been proven reliable in thousands of installations and can provide control for two independent vessels or processes.

  • Sensors

    Panasonic Industrial Devices Sales Company of America

    Panasonic Sensor Solutions offer a wide and constantly evolving range of technologies that provide design engineers with the flexibility to easily choose and implement the Sensor technology best suited for existing and ever-emerging new applications all from a single, world class supplier. Panasonic built-in Sensors contribute to energy savings, safety and comfort. With high-functionality and high-performance, Panasonic has solutions for sensing and detecting rotational speed and angle, position, flow, velocity, temperature, magnetism, currents and much more! Panasonic Sensor products combine the latest technologies with plug-and-play devices such as Grid-EYE® Thermopile Array Sensors, the Ultrasonic Gas Flow Sensor, the highly accurate and flexible 6in1 Sensor (6DoF Automotive Inertial Sensor), a wide array of Passive Infrared Motion Sensors (PIRs), and highly specialized and accurate Industrial Sensors.

  • Regulators

    Parker Hannifin Corp.

    Parker offers a range of air-line, pressure high flow and single phase regulators for instrumentation, filtration, refrigeration and pneumatic applications. Instrumentation regulators are used in the process, power, oil, gas and semiconductor industries to control the flow of liquids and gases with speed and precision. Air regulators provide quick response and accurate pressure regulation for the most demanding industrial air preparation applications, available as miniature, economy, compact, standard, hi-flow and pilot-operated regulators to meet a variety of service needs. The refrigeration line of pressure regulators includes valves that control inlet, outlet or differential pressure. Each regulator is available with an assortment of variations which enable one regulator to perform multiple functions. All regulators are built to the highest quality standards, recognized around the world for their performance, durability and reliability.

  • Photometric Ozone Calibrator

    Model T703 - Teledyne Advanced Pollution Instrumentation

    The Model T703 is a microprocessor controlled ozone calibrator for precision gas analyzers. The Model T703 can deliver concentrations from 50 ppb to 5 ppm at flows from 1 LPM to 5 LPM.The Model T703 has two major components; the ozone generating device and the photometer. The ozone generator produces ozone by passing zero air over a UV lamp. Flow rate and lamp intensity are adjusted to deliver a specified ozone concentration by volume. The temperate and pressure compensated photometer, identical to that of the Model T400 ozone analyzer, provides feedback control of the UV lamp intensity, assuring stable ozone output. A nearly unlimited number of calibration sequences may be programmed into the non-volatile memory of the T703, covering time periods up to a year.

Get Help